CalibR Engineering

PEM and AEM electrolyzer stack design

CalibR Engineering & Consulting designs the mechanical hardware around your membrane and electrodes, from the repeating plate and frame to the endplates and clamping system.

What should an electrolyzer team settle before releasing plate drawings?

Set the boundaries of the repeat cell first. Make room for the active area, seal lands, ports and electrical isolation in the same cross section. Those features compete for plate area. A change to one can force a change to the others after tooling is ordered.

Start with the operating envelope

Define the membrane and electrode dimensions, fluids on each side, expected pressure differences, temperature range and assembly constraints. A PEM layout is a starting reference for an AEM design only where the materials and interfaces suit the new chemistry.

Make one cross section buildable

Trace the seal around every port, check electrical isolation through the stack and show where assembly load passes through the cell. Review the datums and tolerances with the intended plate or frame manufacturing process in mind.

Industrial PEM portfolio example