CalibR Engineering

Engineering deliverables

See how one design question carries through analysis, drawings and procurement.

Calculation packages

Load cases, assumptions, margins and acceptance criteria for a sizing or design review.

ExampleCheck whether the seal retains enough compression at operating pressure.

View example

Check whether the seal retains enough compression at operating pressure.

Request a sample calculation

Design documentation

CAD, dimensioned drawings and a bill of materials for quoting, assembly and inspection.

ExampleSet a flatness tolerance on the plate face that supports the seal.

View example

Set a flatness tolerance on the plate face that supports the seal.

Request a sample drawing

Supplier briefs

Material, finish and inspection requirements a vendor can review with its quote.

ExampleSpecify how the supplier will measure plate flatness and report the result.

View example

Specify how the supplier will measure plate flatness and report the result.

Request a sample brief
Worked example · Does the seal meet its compression target?

For this illustrative calculation, the design target is 16–25% compression. A 1.00 ± 0.02 mm seal closes against a 0.80 ± 0.03 mm gap. Nominal squeeze is 20%.

At the tolerance limits, squeeze ranges from 15.3% to 24.5%. The thinnest seal with the largest gap falls below target. Tightening the assembled gap tolerance to ±0.02 mm raises the minimum to 16.3% and gives a maximum of 23.5%.

Engineering handoff. Record the gap budget in the drawing package, agree how the supplier will inspect the contributing dimensions, and verify the assembled gap before leak testing. These figures are calculated from illustrative inputs.

Explore a stack compression and sealing review

Discuss your project